Primary tabs

FREE SHIPPINGFree shipping on all orders over 100000 INR.

Corrosion Inhibitor Closed Cooling systems

0
No votes yet
SKU::RXSOL-40-4011-210

Product Qty Per Unit: 
220.00
Product usage unit: 
Ltr.

Negotiate Price

Category: 
Evaporator Treat-51
Generic Name: 
Corrosion Inhibitor Additives for closed loop line chilled water to control corrosion and scale
Alkaline Corrosion Inhibitor blend for Metal protection inside the CLOSED circulating system
Product Description: 

Corrosion Inhibitor Additives for Water system
This is a Highly effective INHIBITOR for closed loop , line chilled water with unique dual control of corrosion and scale from system.

This closed water treatment chemicals are  designed to treat hot and chilled water systems. The product contains a combination of nitrite, borate, and silicate formulated to minimize corrosion and deposition. The product comes in a clear and pink appearance form.
 

RXSOL-40-4011-0210 is a superior multifunctional, nitrite-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems. RXSOL-40-4011-0210 is a liquid product containing a combination of ferrous and non-ferrous corrosion inhibitors, a non-carbonate buffer, scale inhibitors, dispersants and a leak detection dye.

Product Application: 

Product Procedure: 

Compatible with Feeders, piping and valves should be made of steel, polyethylene, or PVC. This Treatment can be controlled by a nitrite test.

The recommended dosage of RXSOL-40-4011-0210 is 15.6-23.4 l/m3 of system capacity or 60.6-87 RXSOL-40-4011-0210 of system capacity in all systems. Clean up the system if the system becomes contaminated with iron. Maintain 600-750 ppm nitrite as NO2. RXSOL-40-4011-0210  is intended for industrial use only. It should not be fed to potable water systems

Product Note: 

◦Very effective to Controls corrosion on brass, aluminum, steel, and stainless steel
◦Extends equipment life & Improves overall equipment efficiency

Product Technical Specification: 

Product pack size: 
Alkaline Corrosion Inhibitor blends for Metal protection inside the CLOSED circulating system. RXSOL closed water treatment chemicals are designed to treat hot and chilled water systems. The product contains a combination of nitrite, borate, and silicate formulated to minimize corrosion and deposition. Alkaline inhibitor for closed cooling systems available in 30 Kg Liquid and 220 Kg Drum PACKS.
Product alias: 
<p> Accepta 2807, Korodex 8574, TRASAR TRAC 102, CORRSHIELD NT 4293, Corrosion Inhibitor Multifunctional closed/chilled systems 220 Kg Ltr</p>

RXSOL-40-4011 is a liquid, Nitrite/Borate based compound with unique formulation with organic Corrosion Inhibitors, Anti-Scalant for use in closed cooling water systems , for preventing corrosion and scale Formation in Internal combustion engines, compressor cooling system, DG -set at high or low temperature. It is also acts as a corrosion inhibitor Protects all the metals including cast iron, mild steel, copper etc

Remarks: 

Keep in a tightly closed container in storage closed area . Recommended storage temperature is 500C
 

Corrosion Inhibitor Closed Cooling systems manufacturer and supplier in Mumbai, Kandla, Surat Gujarat, Chennai, Visakhapatnam, Kolkata, Haldia, Fujairah, Sharjah, Ajman, Abudhabi, Dubai, UAE GUlf, Ruwi Barka Muscat Oman, Nairobi Kenya, Sudan Yemen Canada


Product Delivery Locations: 
Kattupalli Port ( L & T Shipbuilding Limited shipyard ), Ennore Port ( Coromondel International Limited Port Area ), Chennai Port, Mugaiyur port, Thiruchopuram port, Silambimangalam Shipyard, Parangipettai port, PY-03 Oil Field, Kaveri port, Vanagiri port, Thirukkadaiyur port, Thirukkuvalai port, Punnakkayal port, Udangudi port, Manappad port, Koodankulam port, Chettinad Tharangambadi Port, Mathur SIDCO Industrial area, Sipcot Industrial Park Malayambakkam