Anti microbial and a powerful anti oxidant for cooling water

Very effective controler of BACTERIA and corrosion from closed loop chilled water system.

Product Description: 

Non-Oxidizing Biocide for Cooling Water Systems – Effective Microbial Control

Non-oxidizing biocide for cooling water systems is a specialized water-treatment chemical designed to control and reduce the growth of bacteria, fungi, algae, and other microorganisms in industrial and commercial water systems. It is commonly used in closed-loop cooling circuits, recirculating cooling towers, air washers, heat exchangers, and industrial water systems.

Microbial growth can result in biofilm formation, slime deposits, fouling, unpleasant odors, reduced heat-transfer efficiency, and microbiologically influenced corrosion (MIC). Regular treatment with a suitable non-oxidizing biocide helps maintain cleaner water systems and supports efficient cooling-system operation.


Very effective controler of BACTERIA and corrosion from closed loop chilled water system.

BIOCIDE for Closed Loop Chilled Water is a powerful microbiocide which will control a wide range of troublesome microbes in both open and closed water systems.

It is a enviromentally safe and versatile anti microbial and a powerful anti oxidant, When it dissolved in water, it disintegrates to water, oxygen and carbon dioxide. All these degradation products are non toxic. It is a very powerful oxidant, whose oxidation potential outranges that of chlorine and chlorine oxides.

Product Application: 

Applications of Cooling Water Biocide

1. Closed-Loop Cooling Systems

Closed-loop cooling systems can experience microbial contamination, particularly when water quality, temperature, or system conditions support microbial growth. A suitable non-oxidizing biocide can help control bacteria and fungi and reduce biological fouling.

2. Recirculating Cooling Towers

Cooling towers continuously recirculate water, creating conditions that can support microbial growth. Biocide treatment helps control algae, bacteria, fungi, slime, and biofilm, supporting efficient heat transfer and cleaner tower operation.

3. Air Washers

Air-washing systems use circulating water and can become susceptible to microbial contamination. A properly selected biocide can help control biological growth and maintain cleaner circulating water.

4. Heat Exchangers

Microbial deposits and biofilm can accumulate on heat-transfer surfaces and reduce heat-transfer efficiency. Biocide treatment can form part of a preventive water-treatment program to control biological fouling.

5. Industrial Process Water Systems

Non-oxidizing biocides are also used in selected industrial water circuits where microbial growth can affect equipment performance, water quality, or production processes.

 

marine / Industrial circulating cooling water for both open and closed loops ( including food contact )
Milk & Dairy products processing and packaging plants.
Wineries, vineyards and breweris plant
Meat, Seafood, poultary and vegetable processing plants
Cleaning, sanitising and disinfections of UF & RO membranes
Waste water treatment ( odour control agent, disinfectant and cleaner )
Hospital & Health care facilities, veterinary clinics
Hatcheries and egg processing unit.
Dish and table ware sanitizer

Product Procedure: 

Product Note: 

What is a Non-Oxidizing Biocide?

A non-oxidizing biocide controls microorganisms through chemical mechanisms that do not depend primarily on oxidation. Unlike oxidizing biocides such as chlorine or bromine-based treatments, non-oxidizing biocides can provide targeted microbial control and are often used as part of a broader cooling-water treatment program.

The selection of an appropriate biocide depends on the system design, water chemistry, microbial population, operating temperature, materials of construction, and regulatory requirements.



Form    :::::  Liquid
Colour ::::   Clear Colourless
Odour  :::: Strong Pungent
pH ( 1% solution ) :::: 1.0 -2.0

Product Technical Specification: 

Specification


Form: Liquid
Colour: Colourless
pH: 3 – 5
Specific gravity: >1.2
Solubility in water: Completely miscible
Boiling point: >100 oC
Decomposition temp: Decomposes at boiling point
Product pack size: 
5, 10, 20, 25, 50, 210 Ltr customised packing as per customer requirement. Ready stock at Mumbai, Gandhidham, Chennai - Ennore, Visakhapatnam, Kolkata, Fujairah - Dubai, Sharjah, Mussafah
Product alias: 
<p> NALCO 7330, Aquacide 2370, Biocide for Closed Loop Chilled Water, Cooling Water Biocide 210 Ltr, NON OXIDIZING Biocide, Glutraldehyde based 210 Ltr</p>

Biocide for Cooling Water System, Non-Oxidizing Biocide, Cooling Tower Biocide, Cooling Water Treatment Chemical, Non-Oxidizing Biocide Supplier, Cooling Water Biocide Supplier, Biocide for Closed Loop Cooling System, Biocide for Recirculating Cooling Tower, Air Washer Biocide, Industrial Water Treatment Biocide, Bacteria Control Biocide, Algae Control Chemical, Fungicide for Cooling Water, Cooling Tower Microbial Control, Cooling System Biocide, Industrial Biocide Supplier, Water Treatment Chemicals, Microbial Control Chemical, Biofilm Control Chemical, Cooling Water Treatment Chemicals.

Key Benefits

A properly selected non-oxidizing cooling-water biocide can provide:

  • Effective control of bacteria

  • Control of fungi and yeast

  • Algae control

  • Reduction of slime and biofilm formation

  • Improved cooling-water hygiene

  • Support for efficient heat transfer

  • Reduced risk of microbiological fouling

  • Compatibility with selected water-treatment programs

  • Useful performance in closed and recirculating systems

Why Microbial Control is Important in Cooling Systems

Microorganisms can multiply rapidly under favorable conditions. Once established, they may produce extracellular polymeric substances that contribute to biofilm and slime formation.

Biological fouling can:

  1. Reduce heat-transfer efficiency

  2. Increase pressure drop and flow resistance

  3. Promote under-deposit corrosion

  4. Contribute to microbiologically influenced corrosion

  5. Increase cleaning and maintenance requirements

  6. Reduce overall cooling-system efficiency

For these reasons, microbial control is an important component of a comprehensive cooling-water treatment program.

Non-Oxidizing vs. Oxidizing Biocides

Both oxidizing and non-oxidizing biocides can be useful in cooling-water treatment, but their mechanisms differ.

Oxidizing biocides control microorganisms primarily through oxidation reactions and may include chlorine-, bromine-, or other oxidizing chemistries.

Non-oxidizing biocides work through other mechanisms that interfere with microbial cellular functions. They are often selected when a particular microbial population needs targeted control or when an oxidizing program is not suitable for the application.

In some systems, oxidizing and non-oxidizing biocides may be used in a carefully designed treatment program to improve overall microbial control.

Cooling Water Biocide Treatment Program

A successful cooling-water treatment program normally considers more than biocide addition alone. Important factors may include:

  • Water quality

  • pH

  • Temperature

  • Microbial counts

  • System volume

  • Blowdown rate

  • Circulation rate

  • Organic loading

  • Biofilm condition

  • Corrosion-control requirements

  • Compatibility with other treatment chemicals

The correct dosage and treatment frequency should be established according to the specific product technical data sheet, water-system conditions, and qualified water-treatment guidance.

Non-Oxidizing Biocide Supplier

When sourcing a non-oxidizing biocide for cooling water systems, industrial users should evaluate product efficacy, compatibility, technical documentation, regulatory status, and supplier support.

A reliable supplier should be able to provide:

  • Technical Data Sheet (TDS)

  • Safety Data Sheet (SDS)

  • Certificate of Analysis (COA), where applicable

  • Recommended application and dosage guidance

  • Packaging options

  • Batch traceability

  • Technical support

Safety and Handling

Biocides are active chemicals and must be handled responsibly. Always review the current Safety Data Sheet (SDS) before use. Appropriate personal protective equipment should be worn, and the product should be stored and handled according to the manufacturer's instructions.

Biocide selection and dosing should also consider applicable local environmental and discharge requirements.

Conclusion

Non-oxidizing biocide for cooling water systems is an important component of microbial-control programs for closed-loop circuits, recirculating cooling towers, air washers, heat exchangers, and industrial water systems.

By controlling bacteria, fungi, algae, and biofilm-forming microorganisms, an appropriate biocide treatment can help reduce biological fouling, support heat-transfer efficiency, and protect cooling-system performance.

For industrial applications, the best results are achieved when the biocide is selected and dosed according to the system's water chemistry, microbial conditions, operating parameters, and treatment objectives.

Remarks: 

Description


BIOCIDE for Closed Loop chilled water is a high performance, broad spectrum organic biocide scientifically formulated for the treatment of open re-circulating cooling systems. RXSOL-40-4008-210 is a superior quality treatment that is ideal for the control of bacteria, fungi and algae in open re-circulating cooling systems and evaporative condensers. RXSOL-40-4008-210 is a proven high performing product that is that can be used where exceptional performance is critical.

RXSOL-40-4008-210 is low foaming and effective over a broad pH range.

 

Application and Dosage


Typically RXSOL-40-4008-210 should be dosed to give 80 ppm (80 g per 1000 lt). Dose at 160 ppm (160 g per 1000 Lt) for heavily fouled systems. Do not mix with other chemicals. Can be dosed by hand or through automatic dosing equipment. It is always advisable to carry out a ‘Control Of Substances Hazardous to Health’ (COSHH) assessment before use. For further technical assistance concerning RXSOL-40-4008-210 please contact us.

Specification


Form: Liquid
Colour: Colourless
pH: 3 – 5
Specific gravity: >1.2
Solubility in water: Completely miscible
Boiling point: >100 oC
Decomposition temp: Decomposes at boiling point

 

Features and Benefits


  • High performance broad spectrum biocide
  • Contains glutaraldehyde
  • Ideal for open re-circulating cooling systems and evaporative condensers
  • Effective against a wide range of bacteria, algae and slimes
  • Effective against Legionella strains, the causitive organism of Legionnaires’ disease
  • Effective against sulphate reducing bacteria
  • Low foaming
  • Effective over broad pH range
  • Can be dosed in conjunction with other organic biocides to help clean up badly fouled systems

BIOCIDE for Closed Loop chilled water is Non oxidizing Microbiocide for bacterial control in open re-circulating system of cooling loop. We are Biocide for cooling water manufacturer, exporter and supplier in Mumbai, Surat, Gandhidham GIDC, Mundra, Manglore, Chennai, Visakhapatnam, Kolkata, Fujairah, Dubai, Sharjah, Abudhabi, Ajman - UAE - Middle East,  Barka - Muscat - Oman.


Product Delivery Locations: 
Kattupalli Port ( L & T Shipbuilding Limited shipyard ), Ennore Port ( Coromondel International Limited Port Area ), Chennai Port, Mugaiyur port, Thiruchopuram port, Silambimangalam Shipyard, Parangipettai port, PY-03 Oil Field, Kaveri port, Vanagiri port, Thirukkadaiyur port, Thirukkuvalai port, Punnakkayal port, Udangudi port, Manappad port, Koodankulam port, Chettinad Tharangambadi Port, Mathur SIDCO Industrial area, Sipcot Industrial Park Malayambakkam