Clog Controller Biocide

0
No votes yet
SKU::RXSOL-40-4009-050

Product Qty Per Unit: 
50.00
Product usage unit: 
Ltr.

Negotiate Price

Category: 
Evaporator Treat-51
Generic Name: 
Microbiocide for cooling water Bacteria and Algae Control.

Strong algae depressant fully compatible with alkalizing and flocculating agents normally used in cooling / boiler water. Algae growth is the main cause of colour in water. Routine and weekly additions of RXSOL-40-4009-050 establish a buffer action to control very rapid algae growth.

Product Description: 

Effective controller of MICRO BIOCIDE and BACTERIA from condensor WATER system.

Clog Controller Biocide is a strong algae depressant fully compatible with alkalizing and flocculating agents normally used in cooling / boiler water.  Algae growth is the main cause of colour in water.  Routine and weekly additions of RXSOL-40-4009-050 establish a buffer action to control very rapid algae growth. 

Product Application: 

Effective controller of MICRO BIOCIDE and BACTERIA from condensor WATER system.

Clog Controller Biocide RXSOL-40-4009-050 is a high performance non-oxidising micro-biocide that uses the latest chemical technologies for the rapid and effective treatment of cooling water systems. RXSOL-40-4009-050 is a rapid acting micro-biocide developed for use in cooling water systems and is effective against Legionella bacteria, SRB’s, algi and fungi. RXSOL-40-4009-050 will also penetrate and disperse biofilm slimes making it an ideal cooling water treatment. RXSOL-40-4009-050  has an excellent environmental profile and is readily biodegradable.

Product Procedure: 

Clog Controller Biocide RXSOL-40-4009-050  is an organic chlorine releasing microbiocide which will effectively control the growth of algal slimes on cooling Water distribution decks, fill, and basins.
This product is recommended for use in industrial process cooling towers, air conditioning cooling systems, and evaporative condensers. It is particularly recommended for use in systems where algae growth is especially difficult to control.

Product Note: 
Where MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 can be used?

For the control of microbial biofilms, bacteria, algae, and fungi, add MICRO BIOCIDE Cooling Water RXSOL-40-4009-050 to industrial recirculating water cooling towers, industrial recirculating closed loop water cooling systems, brewery pasteurizer and can warmer systems. Add MICRO BIOCIDE Cooling Water RXSOL-40-4009-050 at some point in the system to ensure uniform mixing.

Dose Ratio of 
MICRO BIOCIDE Cooling Water RXSOL-40-4009-050 
NOTE: Badly fouled systems should be cleaned before treatment.
 
INITIAL DOSE: if the system is initiating fouling then use 200 ml - 3 ltr of  MICRO BIOCIDE Cooling Water RXSOL-40-4009-050  for per 3000 to 5000 Ltr of water in the system.) Dose can be increased till optimum results.
 
WEEKLY CONTROL DOSE: When microbial control is evident, add 100 to 500 ml per MICRO BIOCIDE Cooling Water RXSOL-40-4009-050  for per 3000 to 5000 Ltr of water in the system
 
AIR WASHER SYSTEMS : Add to the air washer sump or chill water sump to insure uniform mixing, 200 ml  - 3 Ltr of MICRO BIOCIDE Cooling Water RXSOL-40-4009-050  for per 3000 to 5000 Ltr of water in the system, DOSE ration directly proportional of  contamination to control microbial biofilms, bacteria, fungi, and algae which cause fouling in industrial air washer systems.
 


Dose Ratio of MICRO BIOCIDE Cooling Water RXSOL-40-4009-050 for CONTINUOUS FEED METHOD  

Maintain this treatment level by adding a continuous feed of 100 ml to 1000 ml of MICRO BIOCIDE Cooling Water RXSOL-40-4009-050  per 1000 gallon of makeup water).

NOTE : Badly fouled systems must be cleaned before initial treatment.
 
 
 
Dose Ratio of MICRO BIOCIDE Cooling Water RXSOL-40-4009-050 for INDUSTRIAL WASTEWATER TREATMENT SYSTEMS AND SEWAGE SYSTEMS

INITIAL DOSE for Noticeably Fouled Condition: 500 ml - 4000 ml of MICRO BIOCIDE Cooling Water RXSOL-40-4009-050  per 3000 Ltr of water in the system. Repeat until control is achieved. Badly fouled systems should be cleaned before treatment is begun.

SUBSEQUENT DOSE: When microbial control is evident, add 100 ml  - 100 ml MICRO BIOCIDE Cooling Water RXSOL-40-4009-050  per 3000 Ltr of water in the system.
Product Technical Specification: 
Product pack size: 
5, 10, 20, 25, 50, 210 Ltr Microbiocide for cooling water Bacteria and Algae Control.
Product alias: 
<p> GREEN MICROBIOCIDE, MICROORGANISM CONTROL, NALCO ST40-BIOCIDE, CLOG CONTROL 25 Ltr</p>

Strong algae depressant fully compatible with alkalizing and flocculating agents normally used in cooling / boiler water. Algae growth is the main cause of colour in water. Routine and weekly additions of RXSOL-40-4009-050 establish a buffer action to control very rapid algae growth.

GREEN MICROBIOCIDE, MICROORGANISM CONTROL, NALCO ST40-BIOCIDE

Product Benefits

 

  •     Rapid acting micro-biocide.
  •     Effective against Legionella, SRB 's, Algae, Fungi.
  •     Penetrates and disperses biofilm slimes.
  •     Excellent environmental profile (readily biodegradable).
  •     Readily monitored on site.

 

How to control Algae growth in cooling towers, air conditioning cooling systems, and evaporative condensers?

 

RXSOL-40-4009-210  MICRO BIOCIDE Cooling Water RXSOL  is an organic chlorine releasing microbiocide which will effectively control the growth of algal slimes on cooling Water distribution decks, fill, and basins.

This product is recommended for use in industrial process cooling towers, air conditioning cooling systems, and evaporative condensers. It is particularly recommended for use in systems where algae growth is especially difficult to control.

Remarks: 

Clog Controller Biocide RXSOL-40-4009-050 should be dosed periodically at a rate of 75 - 150 ppm of the total system volume. In a badly fouled system an initial dosage rate of up to 250m1/m3 may be required which can be reduced once control is gained.In order to comply with Health & Safety recommendations Clog Controller Biocide RXSOL-40-4009-050 should be alternated with another non-oxidising or oxidizing biocide. It is always advisable to carry out a 'Control Of Substances Hazardous to Health' (COSHH) assessment before use.

BIOCIDE MICRO Cooling Water 20 Ltr manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of BIOCIDE MICRO Cooling Water 20 Ltr at a competitive price from us. We have ready stock of BIOCIDE MICRO Cooling Water 20 Ltr in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.


Product Delivery Locations: 
Kattupalli Port ( L & T Shipbuilding Limited shipyard ), Ennore Port ( Coromondel International Limited Port Area ), Chennai Port, Mugaiyur port, Thiruchopuram port, Silambimangalam Shipyard, Parangipettai port, PY-03 Oil Field, Kaveri port, Vanagiri port, Thirukkadaiyur port, Thirukkuvalai port, Punnakkayal port, Udangudi port, Manappad port, Koodankulam port, Chettinad Tharangambadi Port, Mathur SIDCO Industrial area, Sipcot Industrial Park Malayambakkam