Primary tabs

Chemical Oxygen Demand (COD) Test Kit Manufacturer and Supplier in Tuticorin Port,Chennai Port,Kaaupalli Port Sriperumpudur,Vellore,Bergur,Kanchipuram,Tiruvannamalai,Krishnagiri,Tuticorin,Kudankulam etc.

Ennore Chemical International is a leading Manufacturer and Supplier of. Chemical Oxygen Demand (COD) Test Kit.in Tamil Nadu which has three major ports at Tuticorin, Chennai, Ennore and fifteen minor ports at Cuddalore,
Rameswaram, Kattupalli, Thiruchopuram, Manappad , Kudankulam etc.

COD TEST KIT PROCEDURE

(Chemical Oxygen Demand) Range : 40-800 & 200-4000 ppm

Direction For Use

Rinse Screw Cap, glass tube with distilled water and add 25 drop of Reagent COD TK 1.
Now add 2 ml Water sample with help of syringe (or Pipette) in to the above glass tube.
Take Reagent COD TK 2 in a plastic tube up to the neck (3.5 ml) and transfer it to the above sample solution tube . Close the cap tightly . Mix Well by swirling (Use of safety goggles and hand gloves is recommended )
Take approximately 30-40 ml of paraffin wax in 100 ml glass beaker hit it on a hot plate till temperature up to 150 degree centigrade. (Use Thermometer).

Now emerge the above screw caped glass tube in the hot paraffin oil.
Maintaining the Paraffin oil temperature 140 to 150 degree centigrade and digest the sample for minimum 2 hours . (If strong bubbling observed in to the screw cap glass tube solution then disconnecting heating as it may lead to explosion of glass tube sample may contain volatile constituent and hence this method is not suitable for the above sample discontinue & discard the glass tube solution after cooling. And follow the para 2.

Para 2
After 2 hours solution take out and place it in a fast stand set it cool slowly.
When the solution reach room temperature remove cap and add 2 drop COD TK-3. Mix well and start adding and counting the number of drops while mixing until the color change from bluish green to redish brown (Say ‘X” Drop)
Carry out balance titration using 2 ml distilled water in a 10 ml test jar . Repute above step and put COD TK-4. Note down the number of drop of COD TK4 require to get the solution color change from bluish green to redish brown. (Say “Y”Drops).

COD PPM = X-YX40)

If the expected COD of the test sample is more than 800 PPM then take 20 ml of sample in 100 ml volumetric flask and diluted up to 100 ml with distilled water. Use 2 ml above diluted solution and follow direction as above. Multiply the result obtained by 5.

Caution : Reagent COD TK 2 is acidic , handle carefully and avoid contact with skin.

We commit you the best quality, huge quantity and fast delivery time. Please find link  to get more
details like MSDS, Technical specification of Unipol-RX . If you are interested in our products,
please do not hesitate to drop me an email: ennorecheminternational@gmail.com.  We would like
to assist you immediately. We have ready stock of Unipol-RX available in package size 5,10,25, 50,
200 liters On location in Tuticorin Port, Chennai Port, Ennore Port, Kattupalli Port  in India.

Contact us: http://ennoreindiachemicals.com/contact-us.

 

 

Share this post

Leave a comment

Filtered HTML

  • Web page addresses and e-mail addresses turn into links automatically.
  • Allowed HTML tags: <a> <em> <strong> <cite> <blockquote> <code> <ul> <ol> <li> <dl> <dt> <dd>
  • Lines and paragraphs break automatically.

Plain text

  • No HTML tags allowed.
  • Web page addresses and e-mail addresses turn into links automatically.
  • Lines and paragraphs break automatically.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Image CAPTCHA
Enter the characters shown in the image.

Categories